User Manual
OPERATION AND INSTALLATION MANUAL
KVJEVR718
Enhanced VHF Radio
EVR716
23-11-02
Page 30-1/30-2
2000/02/15
INSTALLATION
1. Environment
The EVR716 transceiver is provided for the following environmental conditions:
− Operating temperature : - 40°C to + 70°C (- 40°F to + 158°F)
− Storage temperature : - 55°C to + 85°C (- 67°F to + 185°F)
− Ventilation : The EVR716 transceiver has an inlet air area on its bottom
face and an outlet air area on its top face (see figure
10-4).
2. First Installation Check Out
Prior to install the EVR716 transceiver, check all interwiring for continuity and isolation.
Install and connect the EVR716 transceiver (see paragraph 3).
Energize the equipment and check that the green LED (PASS) lights on.
3. Mechanical Installation
The EVR716 transceiver is provided to be mounted in a rack in the aircraft. The EVR716
transceiver is equipped with two ARINC 600 attaching lugs (see figure 10-1). The mechanical
installation complies with requirements as defined by the ARINC 600 specifications.
The figures 10-2 and 10-3 show the mechanical characteristics of the EVR716 transceiver.
After installation, energize the equipment and check that the green LED (PASS) lights on.
4. Interwiring
The interwiring complies with requirements as defined by the ARINC 600 specifications.