Safety precautions · The connection and installation of electrical devices may only be carried out by a qualified electrician. · Interventions in and changes to the device result in the voiding of the warranty claim. · Observe your national regulations and the respective safety provisions. · Fixed and flexible conductors of up to 10 mm2 may be attached to the external terminal clips. · Flexible cables with a cross-section ≤ 1 mm2 should not be attached.
OK 3 reset 1 6 12 18 24 D F C1 C E 15:26:38 B G MENU A 1 Res. H I J K General information · The middle communication line shows the selectable menu item. If confirmed with OK, this item is activated. · Flashing texts or symbols require an entry. · If no entries are made within the next 2 minutes, the clock reverts to auto mode.
1. 4 Initial start-up - selection of menu language 1 6 12 18 24 C1 15:26:38 MENU 1 Res. 12H 24H LANGUAGE ESC DATETIME ESC OK MENU SVENSKA ENGLISH SVENSKA ENGLISH OK NORSK OK OK NORSK ESC ESC OK Info In the delivered state the time switch is in the Auto mode with a preset time, date and the menu language English. Prog. 1 6 12 18 24 C1 15:26:38 MENU 1 Res.
Prog. 5 New program REVIEW NEW OK DELETE only with 2-channel version ESC OK FREE 50 CHANNEL SELECT CHANNEL OK I SELECT OK I ESC OK ESC OK SELECT DAY OK CHL ON ESC OK HOURS 00 CHL ON ESC OK MINUTES 15:00 CHL ON ESC OK HOURS 00 OK CHL OFF ESC OK MINUTES 18:00 CHL OFF ESC OK GB SAVED P01 P02 Info The time switch has 50 memory spaces. Example ON command for channel 1 at 3 pm. OFF command at 6 pm. · Select NEW program and confirm with OK. · The free memory spaces are briefly displayed.
Prog. 6 View, edit program DELETE REVIEW OK NEW ESC OK ON OK P01 15:00 HH:MM OFF EDT OK OK P02 18:00 HH:MM Info · The program steps can be scrolled through with . · The respective program can be edited by pressing EDT. The procedure is the same as when creating a new program. EDT OK Delete all programs Info · It is possible to delete all programs with YES · By pressing NO, individual programs can be deleted.
Set date and time Info The date and time are preset at the factory.
Switchover for summer/winter time Info The following settings are possible: PROGRAM DAYLIGHT OK 12H 24H ESC OK AUTO Factory presetting of the published calendar dates. This is automatically recalculated for each year. CALIBRAT AUTO OK NO ESC OK NO CALIBRAT OK AUTO ESC OK SU START 03 MONTH ESC OK NO No switchover SU START 03:21 DAY ESC OK WI START 10 MONTH ESC OK WI START 10:31 DAY ESC OK CALIBRAT Programming. The start date of the summer time and winter time must be entered for this purpose.
Operating mode Info Left-hand button = Channel 1 Right-hand button = Channel 2 (only with 2-channel version) 1 6 12 18 24 C1 15:26:38 MENU 1 Res. Press 1 x = FIX ON = continuous ON Press 2 x = FIX OFF = continuous OFF Press 3 x = return to Auto mode FIX ON: FIX FIX OFF: FIX AUTO: (keine Anzeige) program switching times (no display) programmed Technical Data Dimensions H x W x D Weight g (approx.