Owner's manual
GB
45
Technical data – Relay version
Power supply: 2 x 1.5 V AA LR6 alkaline batteries
Batteryservicelife: 2years(dependingonswitchingfrequency)
Switchingoutput: SPDT(potential-free)
Switchingcapacity: 8(3)A250VAC
Wire cross-section to relay terminals: 0.5 mm
2
– 1.5 mm
2
Roomtemperaturedisplayresolution:0.1ºC
Temperaturesettingdisplay: Program: +5ºC…+32ºC(0.5ºCsteps)
Frostprotection:5ºC(adjustable3ºC…7ºC)
Time setting resolution: Time of day: 1 minute
Program: 30 minutes
Temperature measurement
(heatingsystem): 3K/hour
Programming: weekly program with up to 48 time and temperature programs
changes
Pre-programmedprograms: 4+1user-dened
Protection class/type: II/IP40
Operatingtemperaturerange: Max.45ºC
Operating humidity range: 10% to 90% RH non-condensing
DimensionsHxWxD(mm): 87x154x27