Instructions

SPRING – Wireless weather station
SPRING – Wireless weather station
18 19
7.3.2 Trend pointers
The trend pointers on the display indicate if the temperature and humidity values are currently
RISING, FALLING or STEADY.
7.4 Weather forecast symbols
There are 6 different weather symbols (sunny, slightly cloudy, cloudy, rainy, stormy and snow-
fall).
The weather forecast relates to a range of 12 hours and indicates only a general weather trend.
For example, if the current weather is cloudy and the rain symbol is displayed, it does not mean
the product is faulty because it is not raining. It simply means that the air pressure has dropped
and the weather is expected to get worse but not necessarily rainy.
The sun symbol also appears at night if there is a starry night.
Important note!
Please note that the forecast symbol will become more defined in the course of operation. The
forecast symbol is active right from the start, however, the reliability of the forecasts increases
with the amount of data collected. To begin with, the sensor must adapt initially to the refer-
ence level at the site. The forecast symbol will become at its most reliable after about 30 days.
7.5 Setting of the outdoor temperature and indoor temperature alarm
Press the ALERTS button in normal mode.
HIGH and 60 °C (default) or the last adjusted upper temperature limit appear on the display.
Press and hold the ALERTS button.
The temperature display will be flashing .
Press the or button to set the desired upper limit.
Confirm with the ALERTS button.
LOW and -40°C (default) or the last adjusted lower temperature limit appear on the display.
The temperature display will be flashing.
Press the or button to set the desired lower limit.
Confirm with the ALERTS button.
Set the upper and lower limit for the indoor temperature in the same way.
(Measuring range: 0°C…+50°C / +32°F…+122°F)
7.5.1 Activate and deactivate the outdoor and indoor temperature alarm
To activate or deactivate the respective alarm functions, press the ALERTS button in normal
mode.
HIGH and the last adjusted upper temperature limit is indicated.
Press the button to activate the alarm function.
Press the button to deactivate the alarm function.
The alarm symbol appears/disappears on the display above HIGH.
Press the ALERTS button again to go to the next alarm function and to return to normal mode.
7.5.2 Case of alarm
In the case of an alarm the corresponding symbol will be flashing and an alarm sound is activated.
You can stop the alarm by pressing any button.
7.6 Display of the dew point
Press the HEAT/DEW button, to show the current dewpoint temperature.
On the display appears DEW-POINT and the temperature.
The display automatically switches back to the current display of temperature and humidity.
This interdependency of temperature and relative humidity is expressed by means of the dew-
point: If the air is cooled continuously at constant absolute humidity, then the relative humidi-
ty will steadily increase up to a maximum of 100%. If the air is cooled further, then the excess
water vapour is separated out in the form of water droplets.
8. Positioning and fixing of the basic station and the outdoor transmitter
With the foldable leg at the back of the basic station, the basic station can be placed onto any
flat surface.
With the hanging holes at the back of the basic station, the basic station can be wall mounted
at the respective location. Avoid the vicinity of any interfering field like computer monitors or
TV sets and solid metal objects.
The outdoor transmitter can be placed onto any flat surface or wall mounted at the respective
location by the hanging hole at the back of the unit. Choose a shady and dry position for the
transmitter. (Direct sunshine falsifies the measurement and continuous humidity strains the elec-
tronic components needlessly).
Check the transmission of the signal from the outdoor transmitter to the basic station (transmis-
sion range of up to 60 m free field). Within ferro-concrete rooms (basements, superstructures),
the received signal is naturally weakened.
If necessary choose another position for the outdoor transmitter and/or basic station.
9. Care and maintenance
Clean the instruments with a soft damp cloth. Do not use solvents or scouring agents.
Remove the batteries and pull out the plug of the socket, if you do not use the products for a
long period of time.
Keep the instruments in a dry place.
9.1 Battery replacement
Change the batteries of the outdoor transmitter when the battery symbol appears on the dis-
play of the outdoor values.
Change the batteries of the basic station when the battery symbol appears on the display of the
indoor values.
Please note: When the batteries are changed, the contact between outdoor transmitter and
basic station must be restored – so always insert new batteries into both units or start a manual
outdoor transmitter search.
10. Troubleshooting
Problems Solution
No indication Operation with mains plug:
on the weather station Connect the basic station to mains adapter
Backlight is activated permanently
Control the power adapter
Operation with batteries:
Ensure that the batteries polarity are correct
Press any button to activate the backlight briefly
Change the batteries
No reception of No outdoor transmitter is installed
the outdoor transmitter Check batteries of external transmitter
Display “---“ (do not use rechargeable batteries!)
Restart the outdoor transmitter and the basic station according to
the manual
Start the outdoor transmitter search manually according to the
manual
Choose another place for the outdoor transmitter and/or the basic
station
Reduce the distance between the outdoor transmitter and the basic
station
Check if there is any source of interference
Incorrect indication Change the batteries
TFA_No. 35.1129_Anleit_12_13 27.12.2013 11:24 Uhr Seite 10