Manual

1716
AIR CO
2
NTROL UP Single Beam – CO
2
Monitor
1. Delivery contents
•CO
2
Monitor
USB-Type-C-1,5 m cable and power adaptor
Instruction manual
2. Range of application and all the benefits of your new instrument at a
glance
For monitoring the CO
2
concentration in buildings, where people are
present, eg: schools, offices, public facilities
Single Beam NDIR Sensor
Large CO
2
display with extended traffic light indication (green/yellow/
blue/red)
Display of indoor temperature (°C/°F) and humidity
Memory of the highest and lowest values of CO
2
, temperature and humi-
dity
Alarm function for CO
2
concentration
High contrast display with 4 brightness levels
Manual calibration function for CO
2
sensor
Power connection via USB Type-C cable and power supply (included) or
a suitable USB power source
3. For your safety
This product is exclusively intended for the range of application described
above. It should only be used as described within these instructions.
Unauthorized repairs, alterations or changes to the product are prohibited.
Caution!
Risk of electrocution!
Connect the device using the USB cable and the supplied power supply to
a mains socket installed within your country’s electrical safety regulations
and with a correct mains voltage (see nameplate) or connect the device
via the USB cable to a suitable USB power source such as a computer,
notebook.
The mains socket must be located near the equipment and it must be
easily accessible.
Unplug the device immediately if any fault occurs.
The device and the power adapter must not come into contact with water
or moisture. Only suitable for indoor use.
AIR CO
2
NTROL UP Single Beam – CO
2
Monitor
Do not use the device if the housing, the USB cable or the power adaptor
are damaged.
Operate the device out of reach of persons (including children) who can-
not fully appreciate the potential risks of handling electrical equipment.
Connect the USB cable to the device and the power adaptor first and then
plug the power adapter into the socket.
Route the USB cable lead so that it does not come into contact with sharp-
edged or hot objects.
Important information on product safety!
Do not expose the device to extreme temperatures, vibrations or shocks.
Avoid direct sunshine.
The instrument is not unbreakable. In case of falling down parts can
break.
4. Elements
A: LCD display (Fig. 1):
A 1: CO
2
alarm limit
A 2: CO
2
indication
A 3: Display of minimum values
A 4: CO
2
value > 2000 ppm
A 5: Extended traffic light indication
A 6: Indoor temperature and humidity
A 7: CO
2
alarm symbol
A 8: Display of maximum values
B: Buttons (Fig. 1+2):
B 1: POWER/LIGHT sensor button
B 2: DOWN/CALIBRATE button
B 3: MEM button
B 4: CO
2
SET button
B 5: CO
2
ALARM button
B 6: UP/°C/°F button
B 7: RESET button
C: Housing (Fig. 3):
C 1: USB port
TFA_No. 31.5011_Anleit_10_22 18.10.2022 10:40 Uhr Seite 9