Instructions
2322
AIR CO
2
NTROL UP – CO
2
Monitor
➜ Connect the device with USB cable and
power adapter and charge the battery
➜ Check the connection
Incorrect indication
Display Err ➜ Use a pin to press the RESET button
Indication: LL / HH ➜ Outside measuring range
If your device fails to work despite these measures, contact the retailer
where you purchased the product.
13. Waste disposal
This product and its packaging have been manufactured using high-grade
materials and components which can be recycled and reused. This reduces
waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the
collection systems that have been set up.
Disposal of the electrical device
Caution! This device contains a built-in battery that cannot be
removed without damaging the housing. Improper removal re-
presents a safety risk. Hand in the device unopened at the collec-
tion point; the device and battery will be disposed of properly.
This product is labelled in accordance with the EU Waste
Electrical and Electronic Equipment Directive (WEEE).
Please do not dispose of this product in ordinary household
waste. As a consumer, you are required to take end-of-life devices
to a designated collection point for the disposal of electrical and
electronic equipment, in order to ensure environmentally-compa-
tible disposal. Observe the current regulations in place!
WARNING!
Batteries containing lithium can explode
• Batteries and rechargeable batteries containing lithium (Li=lithium) pre-
sent a high risk of fire and explosion due to heat or mechanical damage
with potentially serious consequences for people and the environment.
Pay particular attention to correct disposal.
AIR CO
2
NTROL UP – CO
2
Monitor
14. Specifications
Power supply USB-Type-C-1.5 m cable with power supply
(included)
Input: 100-240V AC 50/60Hz 0.5A max
Output: 5.0V DC 1.0A, 5.0W
Average active efficiency: ≥73.62%
No-load power consumption: ≤0.10 W
Built-in Li-Ion rechargeable battery
Capacity / Energy 3.7V / 2000 mAh / 7.4Wh
Charging time Approx. 4.5 hours
Battery runtime Approx. 12 hours
(at highest brightness level)
CO
2
Measuring method
Dual Beam Non-Dispersive-Infrared
Technology (NDIR)
Measuring range 400ppm - 5000ppm
Resolution 1 ppm
Accuracy ± 50ppm ± 5%
Update interval 4 seconds
Warm-up time 150 seconds
Recommended operating
temperature range +10…30°C
CO
2
sensor (Ideal conditions also for manual
calibration)
Temperature
Measuring range 0 °C… +50°C (32°F...122°F)
Resolution 0.1°C
Accuracy ±1 °C
Humidity
Measuring range 25…95%RH
Resolution 1% RH
Accuracy ±5% RH
Housing dimension 77 x 96 x 144 mm
Weight 203 g (device only)
TFA_No. 31.5010_Anleit_02_22 22.02.2022 13:57 Uhr Seite 12