Instructions

2120
AIR CO
2
NTROL UP – CO
2
Monitor
7. Traffic light display
The CO
2
monitor shows the CO
2
comfort level with an extended traffic
light display:
8. CO
2
upper limit
Press briefly the CO
2
SET button in normal mode. and 2000 ppm
(default) or the last adjusted upper CO
2
limit appear on the display. After
3 seconds, the device automatically returns to the normal mode.
Press and hold the CO
2
SET button for 2 seconds to enter the setting
mode. The value flashes.
Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper
limit in steps of 10ppm, while the value flashes.
Press and hold the DOWN/CALIBRATE or UP/°C/°F button in setting mode
for fast mode.
Confirm the setting with the CO
2
SET button.
The device will automatically quit the setting mode if no button is pressed
for 20 seconds. The setting is saved.
Press the CO
2
ALARM button in normal mode, to activate or deactivate the
alarm function for the upper CO
2
limit. appears on the display when
the alarm is activated.
If the measured CO
2
value is above the upper limit setting, an alarm
sounds and the CO
2
alarm symbol flashes. Press any button to stop the
alarm sound. The CO
2
alarm symbol will continue flashing until the mea-
sured CO
2
value is below the set alarm limit.
9. CO
2
, temperature and humidity maximum and minimum values
Press the MEM button in normal mode.
You can now read the highest measured values for CO
2
, temperature and
humidity of the last 24 hours (display MAX).
AIR CO
2
NTROL UP – CO
2
Monitor
Press the MEM button again.
The minimum values measured since the last 24 hours appear on the dis-
play (display MIN.
Press the MEM button again to return to normal mode. The device will
automatically quit the MAX/MIN mode if no button is pressed for 3 se-
conds.
Press and hold the MEM button for 2 seconds during the highest or low-
est values are displayed. The values will be deleted (display ----) and reset
to the current state.
10. CO
2
manual calibration function
For the whole calibration process, place the device outdoors. Choose a
shady and dry place. Wait 15 minutes, the device must adapt to the envi-
ronment.
Use a pin to press the RESET button at the bottom. Wait until the normal
display appears (see point 6. “Operation”).
Then press and hold the DOWN/CALIBRATE button for 2 seconds to enter
the manual calibration mode. The CAL symbol flashes.
Wait approx. 20 minutes, until the normal display with a CO
2
concentra-
tion of 400 ppm (fresh air) appears. The calibration is completed and the
device returns to normal state. Now you can use the device again as usual.
During the manual calibration operation, press the DOWN/CALIBRATE but-
ton to exit the calibration mode.
11. Care and maintenance
Clean the device with a soft damp cloth. Do not use solvents or scouring
agents.
Turn off the device if you do not use it. Press the POWER/LIGHT sensor
button for 3 seconds.
Store the device in a dry place.
12. Troubleshooting
Problem Solution
No display on the device Press the POWER/LIGHT button for
3 seconds to switch on the device
Set the brightness with the POWER/LIGHT
button
CO
2
value (ppm) Description
400-600 GOOD
601-1000 NORMAL
1001-1500 POOR
1501-2000 SERIOUS
2000 SERIOUS +
TFA_No. 31.5010_Anleit_02_22 22.02.2022 13:57 Uhr Seite 11