This output has two switching outputs that react as follows in case of an 
alarm on channel 1. 
Switch point 1, active when the temp. or rH is exceeded on channel 1. 
Switch point 2, active when the temp. or rH is undershot on channel 1. 
A  switch  point  is  active  as  long  as  the  alarm  limit  is  triggered  and 
deactivated  again  as  soon  as  the  respective  value  is  again  within  the 
standard range or the respective alarm setting is deactivated. 
The  open  collector  output  has  a  jack  for  a  3.5  mm  jack  plug.  The 
following drawing shows the configuration. 
Technical specifications: 
Maximum switching voltage: 24V. DC 
Maximum switching current: 400 mA 
Note: 
Comply with the technical specifications. 
Jack 
switch point 1 
- high alarm - 
switch point 2 
- low alarm - 
C = switch point 1, high alarm 
B = switch point 2, low alarm 
A = ground 