Datasheet

Texcell-NetCom Co., Ltd. All rights reserved.
- 122 -
2. CONTACT
DATA
Contact Arrangement 1 Form A 1 Form B
1 Form C
NO NC
Contact Resistance 50mΩ max. (at 1A 24VDC)
Contact Material AgSnO
2
Max. Switching Voltage 277VAC / 28VDC
Max. Switching Current 40A 15A 20A 10A
Max. Switching Power 7200VA / 560W 3600VA / 280W
4800VA / 560W
2400VA / 280W
Contact rating
30A 240VAC
20A 28VDC
15A 240VAC
10A 28VDC
20A 240VAC
20A 28VDC
10A 240VAC
10A 28VDC
Life Expectancy
Electrical 100,000 operations
Mechanical 10,000,000 operations
3. CHARACTERISTICS
Insulation Resistance 1000MΩ (at 500VDC)
Dielectric
Strength
Open Contacts 1500VAC 1min
Contacts and Coil
“B” type: 4000VAC 1min
Others: 2500VAC 1min
Operate Time (at nominal voltage) DC type: 15ms max.
Release Time (at nominal voltage) DC type: 10ms max.
Temperature Range
DC: -55 ~ 85
AC: -55 ~ 60
Shock
Resistance
Functional
98
m/s
2
Destructive
980
m/s
2
Vibration Resistance 10 ~ 55Hz, 1.5mm DA
Humidity 5 ~ 85% RH
Termination PCB, PCB & QC
Construction Plastic sealed type, Open type(only for DC coil)
Weight Approx. 36g
Outline Dimension (L x W x H)
PCB: 32.3 x 27.1 x 20.0 mm
PCB & QC: 32.4 x 27.5 x 27.8 mm
Note: 1) For plastic sealed type, the venting-hole should be excised in test. Typical electrical load & endurance: at 30A 240VAC, Resistive, at room
temperature, 100,000 OPS, for NO contact.
2) The data shown above are initial values.
3) Please find coil temperature curve in the characteristic curves below.
4) UL insulation system: Class F, Class B