Datasheet

Texcell-NetCom Co., Ltd. All rights reserved.
- 121 -
Miniature High Power Relay
CT
1. COIL
DATA (at 23)
1)
DC Type
Nominal
Voltage (VDC)
Pick-up
Voltage (VDC)
Drop-out
Voltage (VDC)
Max Allowable
Voltage (VDC)
Coil Current
(mA)(±10%)
Coil Resistance
(Ω)
Coil Power
(mW)
5 3.75 0.5 6.50 180 27 x (1±10%)
Approxi.
900
6 4.50 0.6 7.80 150 40 x (1±10%)
9 6.75 0.9 11.7 100 97 x (1±10%)
12 9.00 1.2 15.6 75.0 155 x (1±10%)
15 11.25 1.5 19.5 60.0 256 x (1±10%)
18 13.50 1.8 23.4 50.0 380 x (1±10%)
24 18.00 2.4 31.2 37.5 660 x (1±10%)
48 36.00 4.8 62.4 18.8 2560 x (1±10%)
70 52.50 7.0 91.0 12.9 5500 x (1±10%)
110 82.50 11 143 8.18 13450 x (1±10%)
2)
AC Type
Nominal
Voltage (VAC)
Pick-up
Voltage (VAC)
Drop-out
Voltage (VAC)
Max Allowable
Voltage (VAC)
Coil Current
(mA)(±10%)
Coil Resistance
(Ω)
Coil Power
(VA)
12 9.60 2.4 15.6 167 25 x (1±10%)
Approxi.
2
24 19.2 4.8 31.2 83.3 100 x (1±10%)
120 96.0 24 156.0 16.7 2500 x (1±10%)
208 166.4 41 270.4 9.62 11000 x (1±10%)
220 176 44 286.0 9.10 13490 x (1±10%)
240 192 48 286.0 8.30 13490 x (1±10%)
277 220 54 360.1 7.22 15000 x (1±10%)
Note: 1) When requiring pick-up voltage <80% of nominal voltage, special order allowed.
2) The data shown above are initial values at 50Hz. When requiring 60Hz, special order allowed.
Features
● 40A switching capability
● 4kV dielectric strength
(between coil and contacts)
● Heavy load up to 7,200VA (File No.:E134581)
● PCB coil terminal, ideal for duty load
● Unenclosed and plastic sealed type available
● UL insulation system: Class F available

Summary of content (5 pages)