Datasheet

Texcell-NetCom Co., Ltd. All rights reserved.
- 68
-
4. ORDERING
INFORMATION
CS 11 - 12 SH
Relay Model
CS
Contact Arrangement
11: 1 Form A (SPST-NO)
1: 1 Form C (SPDT)
Coil Voltage
3=3VDC, 5=5VDC, 6=6VDC, 9=9VDC, 12=12VDC, 18=18VDC,
24=24VDC, 48=48VDC
Contact Capacity & Coil Power
SH: 5A 250VAC/30VDC, Coil Power 450mW (only for 1 Form A)
3A 250VAC/30VDC, Coil Power 450mW (only for 1 Form C)
SGH: 10A 250VAC / 30VDC, Coil Power 450mW (only for 1 Form A)
H: 3A 250VAC/30VDC, Coil Power 200mW (only for 1 Form A)
Q: 8A 250VAC, Coil Power 200mW (only for 1 Form A)
5. DIMENSIONS (Unit: mm)
Outline Dimensions
1 Form A 1 Form C
Wiring Diagram (Bottom View)
1 Form A 1 Form C
PCB Layout (Bottom view)
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.54mm.