Datasheet
7
®
XTR112, XTR114
TYPICAL PERFORMANCE CURVES (CONT)
At T
A
= +25°C, and V+
= 24V, unless otherwise noted.
Temperature (°C)
REFERENCE CURRENT ERROR
vs TEMPERATURE
+0.05
0
–0.05
–0.10
–0.15
–0.20
Reference Current Error (%)
–75 –50 –25 0 25 50 75 100 125
Typical production distribution
of packaged units.
XTR112 and XTR114 included.
Current Source Drift (ppm/°C)
CURRENT SOURCE DRIFT
PRODUCTION DISTRIBUTION
40
35
30
25
20
15
10
5
0
Percent of Units (%)
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
Typical production distribution
of packaged units. XTR112 and
XTR114 included.
Current Source Matching Drift (ppm/°C)
CURRENT SOURCE MATCHING
DRIFT PRODUCTION DISTRIBUTION
90
80
70
60
50
40
30
20
10
0
Percent of Units (%)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
–1 –0.5 0 0.5 1 2.521.5
V
REG
Output Current (mA)
XTR114 V
REG
OUTPUT VOLTAGE
vs V
REG
OUTPUT CURRENT
3
5.35
5.30
5.25
5.20
5.15
5.10
5.05
5.00
V
REG
Output Voltage (V)
NOTE: Above 2.4mA,
zero output degrades
25°C
125°C
–55°C
–1 –0.5 0 0.5 1 2.521.5
V
REG
Output Current (mA)
XTR112 V
REG
OUTPUT VOLTAGE
vs V
REG
OUTPUT CURRENT
3
5.35
5.30
5.25
5.20
5.15
5.10
5.05
5.00
V
REG
Output Voltage (V)
NOTE: Above 2.1mA,
zero output degrades
25°C
125°C
–55°C