Table 2-11. Miscellaneous Terminals (continued)
BALL NO.
I/O
SIGNAL DESCRIPTION
ZAY ZAJ
TYPE
PACKAGE PACKAGE
SDA H12 H11 I/O Serial-bus data. This signal is used as serial bus data when a pullup is detected on
SDA or when the SBDETECT bit is set in the serial bus control and status register.
Note: In serial-bus mode, an external pullup resistor is required to prevent the SDA
signal from floating.
BMODE A05 B06 I Beta mode. This terminal determines the PHY-section/LLC-section interface
connection protocol. When logic high (asserted), the PHY-section/LLC-section
interface complies with the IEEE Std 1394b-2002 Revision 1.33 beta interface.
When logic low (deasserted), the PHY-section/LLC-section interface complies with
legacy IEEE Std 1394a-2000. This terminal must be pulled high with a 1-kΩ resistor
during normal operation.
TESTM B02 A03 I Test control. This input is used in the manufacturing test of the XIO2213B. For
normal use, this terminal must be pulled high through a 1-kΩ resistor to V
DD
.
VREG_PD A06 B07 I Voltage regulator power-down input. When asserted logic high, this pin will power-
down the internal 3.3- to 1.95V regulator. For single 3.3V supply operation, this pin
should be tied to GND. When using the internal regulator, the XIO2213B can
support a maximum of 2-Beta and 1-DS connection simultaneously. If 3-Beta ports
are required to be simultaneously supported, it is recommended to use an external
1.95V regulator.
SE P13 M10 I Test control. This input is used in the manufacturing test of the XIO2213B. For
normal use, this terminal must be pulled low either through a 1-kΩ resistor to GND
or directly to GND.
SM P14 N10 I Test control. This input is used in the manufacturing test of the XIO2213B. For
normal use, this terminal must be pulled low either through a 1-kΩ resistor to GND
or directly to GND.
30 Overview Copyright © 2008–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: XIO2213B