Datasheet

XIO2213B
www.ti.com
SCPS210F OCTOBER 2008REVISED MAY 2013
Table 10-2. Base Register Field Description (continued)
FIELD SIZE TYPE DESCRIPTION
Max_Legacy_S 3 Rd Maximum legacy path speed. This field holds the maximum speed capability of any legacy node (IEEE
PD Std 1394a-2000 or 1394-1995 compliant) as indicated in the self-ID packets received during bus
initialization. Encoding is the same as for the PHY_SPEED field (but limited to S400 maximum).
BLINK 1 Rd Beta-mode link. This bit indicates that a beta-mode-capable LLC section is attached to the PHY section.
This bit is set by the BMODE input terminal on the XIO2213B and should be set to 1.
Bridge 2 Rd/Wr Bridge. This field controls the value of the bridge (brdg) field in the self-ID packet. The power reset value
is 0. Details for when to set these bits are specified in the IEEE Std 1394.1 bridging specification.
Page_Select 3 Rd/Wr Page select. This field selects the register page to use when accessing register addresses 8-15. This
field is reset to 0 by a hardware reset and is unaffected by bus reset.
Port_Select 4 Rd/Wr Port select. This field selects the port when accessing per-port status or control (for example, when one
of the port status/control registers is accessed in page 0). Ports are numbered starting at 0. This field is
reset to 0 by hardware reset and is unaffected by bus reset.
The port status page provides access to configuration and status information for each of the ports. The
port is selected by writing 0 to the Page_Select field and the desired port number to the Port_Select field
in base register 7. Table 10-3 shows the configuration of the port-status page registers, and Table 10-4
gives the corresponding field descriptions. If the selected port is not implemented, all registers in the port
status page are read as 0.
Table 10-3. Page 0 (Port Status) Register Description
BIT POSITION
ADDRES
S
0 1 2 3 4 5 6 7
1000 Astat Bstat Ch Con RxOK Dis
1001 Negotiated_speed PIE Fault Standby_fault Disscrm B_Only
1010 DC_connected Max_port_speed (011b) LPP Cable_speed
1011 Connection_unreliable Reserved Beta_mode Reserved
1100 Port_error
1101 Reserved Loop_disable In_standby Hard_disable
1110 Reserved
1111 Reserved
Copyright © 2008–2013, Texas Instruments Incorporated Physical Layer (PHY) Section 183
Submit Documentation Feedback
Product Folder Links: XIO2213B