Datasheet
XIO2213B
SCPS210F –OCTOBER 2008–REVISED MAY 2013
www.ti.com
7.23 Subsystem Access Register
Write access to the subsystem access register identically updates the subsystem ID registers to OHCI-
Lynx. The system ID value written to this register may also be read back from this register. See Table 7-
19 for a complete description of the register contents.
PCI register offset: F8h
Register type: Read/Write
Default value: 0000 0000h
BIT NUMBER 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RESET STATE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
BIT NUMBER 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RESET STATE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Table 7-19. Subsystem Access Register Description
BIT FIELD NAME TYPE DESCRIPTION
31-16
(1)
SUBDEV_ID RW Subsystem device ID alias. This field indicates the subsystem device ID.
15-0
(1)
SUBVEN_ID RW Subsystem vendor ID alias. This field indicates the subsystem vendor ID.
(1) These bits shall only be reset by a fundamental reset (FRST). FRST is asserted (low) whenever PERST or GRST is asserted.
130 1394 OHCI PCI Configuration Space Copyright © 2008–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: XIO2213B