Datasheet
Description
www.ti.com
5 EVM Status LEDS .......................................................................................................... 8
6 UCD90SEQ64EVM-650 Bill of Materials .............................................................................. 16
1 Description
UCD90SEQ64EVM-650 allows any of TI’s 64-pin sequencers to be installed into the onboard socket for
evaluation. Access to all of the user input/output (I/O) is provided via strip connectors for integration into
complex systems using clip-type jumper wires.
UCD90SEQ64EVM-650 allows direct PMBus (power management bus) communication with the
sequencer via an onboard USB interface. This interface allows direct control of and feedback from the
sequencer when using the TI Fusion Digital Power Designer graphical user interface (GUI).
Table 1. Sequencers Summary
64-Pin (RGC) Number of Number of
Description
Device Part No. Voltage Rails Fans
UCD90120 Generation 1 12-rail sequencer and system health monitor 12 (13 monitor inputs) 0
(released) 10 rails with margining
UCD90124 Generation 1 12-rail sequencer and system health monitor with fan 12 (13 monitor inputs) 4
(released) control 10 rails with margining
UCD90910 Generation 1+ 10-rail sequencer and system health monitor with fan 10 (13 monitor inputs) 10
(released) control 10 rails with margining
UCD90160 Generation 2 16-rail sequencer and system health monitor 16 (16 monitor inputs) 0
(release in 2011) 10 rails with margining
UCD90120A Generation 2 12-rail sequencer and system health monitor 12 (13 monitor inputs) 0
(release in 2011) 10 rails with margining
UCD90124A Generation 2 12-rail sequencer and system health monitor with fan 12 (13 monitor inputs) 4
(release in 2011) control 10 rails with margining
1.1 Features
• General Features
– USB port powered or power with single 5-V supply
– JTAG programming port for "in socket" device configuration
– Serial port for advanced debugging
– Status LED’s on all GPIO
– Strip connector I/O access
– USB-PMBus interface for communication
– UCD90124 (in socket) and mini-USB cable provided
1.2 Sequencer Applications
• Industrial/ATE
• Telecommunications and networking equipment
• Servers and storage systems
• Any system requiring sequencing and monitoring of multiple power rails
2 Quick Start
2.1 Test Setup
Figure 1 shows a typical test setup for UCD90SEQ64EVM-650. All that is required is a personal computer
(PC) with a USB port and the TI Fusion Digital Power Designer GUI. The USB-EVM cable is provided with
the EVM and is used for EVM power.
When installing other UCD90xxx sequence devices into XU1, ensure that the device pin 1 is oriented as
shown in Figure 1.
2
UCD90SEQ64EVM-650:— 64-Pin Sequencer Development Board SLVU423–December 2010
Submit Documentation Feedback
© 2010, Texas Instruments Incorporated