5 IC Grounding and Layout Recommendations
Two grounds are recommended: AGND (analog) and DGND (digital).
AGND plane should be on a different layer than DGND, and right under the UCD3138 device.
UCD3138 power pad should be tied to AGND plane by at least 4 vias
AGND plane should be just large enough to connect to all required components.
Power ground (PGND) can be independent or combined with DGND
The power pad of the driver IC should be tied to DGND
Both 3.3VD and 3.3VA should have a local 4.7µF capacitor placed as close as possible to the device
pins
BPCAP decoupling (2.2 µF typically) MUST be connected to DGND
All analog signal filter capacitors should be tied to AGND
If the gate driver device, such as UCD27524 or UCD27511/7 driver is used, the filter capacitor for
the current sensing pin can be tied to DGND for easy layout
All digital signals, such as GPIO, PMBus and PWM are referenced to DGND.
The RESET pin capacitor (0.1µF) should be connected to either DGND or AGND locally. A 10k pull-
up resistor to 3.3V is recommended.
All filter and decoupling capacitors should be placed close to UCD3138 as possible
Resistor placement is less critical and can be moved a little further away
The DGND and AGND net-short resistor MUST be placed right between one UCD3138’s DGND pin
and one AGND pin. Ground connections to the net short element should be made by a large via (or
multiple paralleled vias) for each terminal of the net-short element.
If a gate driver device such as UCC27524 or UCC27511/7 is on the control card and there is a PGND
connection, a net-short resistor should be tied to the DGND plane and PGND plane by multiple vias. In
addition the net-short element should be close to the driver IC.
Configure all unused GPIO as inputs and connect them to ground.