Datasheet
SLUU166A - December 2003 − Revised February 2004
11
UCC39002 Advanced Load-Share Controller User’s Guide, HPA027A
7 List of Materials
REFERENCE QTY DESCRIPTION MANUFACTURER PART NUMBER
C1, C2, C3, C4, C6,
C8
6 Capacitor, ceramic, X5R or better, CSA compensation,
0805
TBD TBD
C10, C11, C12 3 Capacitor, ceramic, X5R or better, EA compensation,
1210
TBD TBD
C5, C7, C9 3 Capacitor, ceramic, 0.47 µF, 25 V, X7R, ±10%, 0805 TDK Corporation C2012X7R1E474K
Q1, Q2, Q3 3 MOSFET, N-channel, 60 V, 115 mA, 1.2 Ω, SOT23 Vishay−Liteon 2N7002DICT
R1, R2, R3 3 Resistor, chip, 47 kΩ, 1/10 W, ±5%, 0805 Panasonic − ECG ERJ−6GEYJ473V
R4, R5, R6, 3 Resistor, chip, 1 kΩ, 1/10 W, ±5%, 0805 Panasonic − ECG ERJ−6GEYJ102V
R7, R8, R9, R19,
R20, R21
6 Resistor, chip, 1/10 W or better, ±5% or better, CSA com-
pensation, 0805
TBD TBD
R10, R11, R12, R13,
R14, R15
6 Resistor, chip, 1 W, ±5% or better, current sense, 2512 TBD TBD
R16, R17, R18, R22,
R23, R24
6 Resistor, chip, 1/10 W or better, ±5% or better, CSA com-
pensation, 0805
TBD TBD
R25, R26, R27 3 Resistor, chip, 1/10 W or better, ±5% or better, voltage
adjustment, 0805
TBD TBD
R28, R29, R30 3 Resistor, chip, 1/10 W or better, ±5% or better, EA com-
pensation, 0805
TBD TBD
TB1, TB2, TB3, TB4,
TB5
5 Terminal block, 2 pin, 15 A, 5.1 mm, 0.40 x 0.35 OST ED1609
U1, U2, U3 ** 3 IC, Advanced Load Share Controller, SO8 Texas Instruments UCC39002D
JP1, JP2, JP3 3 Header, 3 pin, 100-mil spacing, 36-pin strip, 0.100 x 3” Sullins PTC36SAAN
JP4, JP5 2 Header, 2 pin, 100-mil spacing, 36-pin strip, 0.100 x 2” Sullins PTC36SAAN
J1, J2, J3, J4, J5, J6,
J7, J8
8 Lug, solderless, #10−12 AWG, copper/tin, uninsulated,
0.375 x1.00
AMP 33457
N/A 5 Shunt for JP1, JP2, JP3, JP4, JP5, 0.100” Sullins STC02SYAN
N/A 8 Input and output lugs for V+ and V− pads, 0.765” Solis 8−33457−1
N/A 8 Screw, roundhead, phillips, #8−32 1/4”, 0.35” Std Std
N/A 8 Star washer, #8, 0.36” Std Std
N/A 8 Nut, medium #8, 0.245” Std Std
NOTES: 1. These assemblies are ESD sensitive, ESD precautions shall be observed.
2. These assemblies must be clean and free from flux and all contaminants. Use of no clean flux is not acceptable.
3. These assemblies must comply with workmanship standards IPC−A−610 Class 2.
4. Ref designators marked with an asterisk (’**’) cannot be substituted. All other components can be substituted with equivalent MFG’s
components.
5. Install lugs with appropriate hardware per Figure 4,below. Ensure the lug is seated on the square pad for good contact.