DETAILED DESCRIPTION
soft-start
The soft-start section contains all the circuitry required to produce a user programmable slowly increasing PWM
duty cycle, starting from 0% to a maximum of 72%. The soft-start cycle is triggered either by the initial
primary-side startup procedure or after any one of three user-programmable fault conditions and one fixed fault
condition. The PWM duty cycle increases according to the charge rate of an user-selectable external soft-start
capacitor, connected from the SS pin to GND. The SS capacitor is charged by a nominal 7-µA internal current
source.
Should the CS pin rise in voltage above 1.375 V, a soft-start cycle is triggered. The soft-start cycle disables the
output driver OUT and holds it in the low state until the capacitor connected from the SS pin to GND is discharged
below 1.0 V by an internal 5-µA current sink. After this discharge period, the PMW output OUT is enabled and
the duty cycle is allowed to slowly increase as before.
synchronization
The SS pin and the FB pin accepts the secondary-side of a small signal synchronization transformer. A series
blocking capacitor inserted in the primary-side of the synchronization transformer is intended to differentiate the
square-wave gate drive output of the secondary-side PWM controller while preventing the transformer from
saturation. The soft-start capacitor also provides an ac GND at the SS pin or the synchronization transformer
secondary. The small signal synchronization transformer provides galvanic isolation between primary and
secondary side and must have adequate voltage breakdown rating between the primary and secondary
windings.
Two comparators, with an approximate 1.0-V offset each, are connected to the FB pin to provide plus and minus
differential voltage comparison with a 2.0-V deadband between the FB and SS pins. The 2.0-V deadband
prevents inductive backswing of the small-signal transformer from giving false secondary-side pulse-edge
detection.
Enough energy must be coupled into the comparator differential inputs to ensure reliable comparator switching.
This requires sufficient voltage overdrive above the 1.0-V comparator threshold and a specified transformer
circuit time constant to provide a minimum synchronization pulse width.
On receiving the first recognizable negative going voltage pulse (turnoff command) generated from the falling
edge of the differentiated square-wave gate drive signal on the secondary-side, the PWM latch is reset and a
synchronization latch is set. After this event, all primary-side PMW driver output is slaved to the secondary-side
driver output in both frequency and duty cycle. The triggering of a soft-start cycle by a fault condition resets the
synchronization latch to again allow the internal startup oscillator to control the PWM latch.
PWM
The PWM section consists of a reset dominant SR latch with necessary logical gating on the set input to allow
control from the free running startup oscillator until feedback from the secondary-side PWM gate drive output
is detected. After the occurrence of detectable feedback from the secondary-side gate driver, the control of the
primary-side PWM latch is handed off to the secondary-side PWM controller. A nine-input OR gate on the PWM
latch reset dominant input allows the numerous fault conditions to reset the PWM latch and control from either
the startup oscillator or feedback from the secondary-side PWM output driver.