Test Setup
www.ti.com
4 Test Setup
Safety: This evaluation module is not encapsulated and there are voltages that are much greater than 50
V DC.
• If you are not trained in the proper safety of handling and testing power electronics please do not use
this evaluation module.
Voltage Source: Isolated AC source or variable AC transformer capable of 265-V AC cable of handling
10 W.
Voltmeter: One digital voltage meter.
Power Analyzer: Capable of measuring 1 mW to 10 W of input power and capable of handling 265-V
RMS input voltage. Most power analyzers require a precision shunt resistor for measuring input current
and input power of 5 W or less. Please read the power analyzer’s user manual for proper setup.
Oscilloscope:
• 4 channel, 100 MHz.
• Probes capable of handling 600 V.
Output Load: Resistive or electronic load capable of handling 5 W at 5 V.
Recommended Wire Gauge: Insulated 22 AWG.
Figure 3. Test Setup
5 Test Point Description
Table 2. Test Point Functions
TEST POINTS NAME DESCRIPTION
TP1 AC Line Kelvin connection for AC Line
TP2 AC Neutral Kelvin connection for AC neutral
TP3 VOUT + Kelvin connection for VOUT +
TP4 VOUT - Kelvin connection for VOUT -
6
UCC28700EVM-068 5-W USB Adapter SLUU968–July 2012