Datasheet
www.ti.com
Performance Data and Typical Characteristic Curves
Figure 20. Output Short Circuit Protection
(Short circuit maintained on output; note the output current goes to 4.62 A, refer to equation 13 in the
data sheet, during the 250-ms delay to overload fault, t
OL
, and retries after t
RETRY
= 750 ms. Input voltage =
85 V
AC
. Ch.1 = I
OUT
, 1 A/div., Ch. 3 = V
OUT
, 1 V/div.)
Figure 21. Output Over Voltage Protection
(The EVM was tested with an open FB loop, no load. OVP threshold is equal to 15.44 V. Ch. 3 = V
OUT
, 2
V/div., offset by 4 V.)
21
SLUU383C– November 2009– Revised June 2011 UCC28610EVM-474 25-W Universal Off-Line Flyback Converter
Submit Documentation Feedback
Copyright © 2009–2011, Texas Instruments Incorporated