Datasheet
FAN
V2
Load 1
3.3V/25A
+ -
+ -
+ -
DC
Source
V1
A1
- +
www.ti.com
Test Setup
5 Test Setup
5.1 Test Equipment
Voltage Source: HP 6015A DC Power Supply
Multimeters: Fluke 45 Dual Display Multimeter
Output Load: HP 6060A DC Electronic Load
Oscilloscope: Tektronix TDS 460 A, 400 MHz
Fan: 200 LFM minimum compatible
Recommended Wire Gauge: AWG #18 for input voltage connection. AWG #16 for output load
connection.
5.2 Recommended Test Setup
Figure 2. Recommended Test Set Up
5
SLUU429B–June 2010–Revised December 2010 Half-Bridge DC-to-DC Converter With Primary-Side Control
Submit Documentation Feedback
© 2010, Texas Instruments Incorporated