Datasheet

UCC28089
SLUS623A -- SEPTEMBER 2004 -- REVISED AUGUST 2006
3
www.ti.com
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature (unless otherwise noted)
}
PARAMETER SYMBOL RATING UNITS
Supply voltage (I
DD
<10mA) V
DD
15 V
Supply current I
DD
20 mA
OUTA/OUTB sink current (peak) I
OUT(sink)
1.0
A
OUTA/OUTB source current (peak) I
OUT(source)
-- 0 . 5
A
SYNC sink current (peak) 50
m
A
SYNC source current (peak) -- 5 0
m
A
Analog inputs (DIS, CT, CS) --0.3toV
DD
+ 0.3, not to exceed 5 V
Power dissipation at T
A
=25°C (D package) 650
m
W
Power dissipation at T
A
=25°C (DRB package) TBD
mW
Junction operating temperature T
J
--55 to 150
Storage temperature T
stg
--65 to 150
o
C
Lead temperature (soldering, 10 sec.) T
sol
+300
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating c onditions” is not
implied. Exposure to absolute--m aximum--rated conditions for extended periods may affect device reliability.
All voltages are with respect to GND. Currents are positive into, negative out of the specified terminal. Consult P ackaging Section of the Databook
for thermal limitations and considerations of packages.
RECOMMENDED OPERATION CONDITIONS
Parameter Symbol MIN TYP MAX UNITS
Supply voltage (I
DD
<10mA) V
DD
8.5 14 V
SYNC sink current (peak) 0 10 25
m
A
SYNC source current (peak) -- 2 5 -- 1 0 0
m
A
Analog inputs (DIS, CT, CS) 0 4 V
Timing capacitor range CT 100 100,000 pF
Timing charge resistor range RA 32 750
k
Discharge resistor range RB 0 250
k
Timing charge current I
CHG(RA+RB)
10 300 μA
Switching Frequency f
SW
1000 kHz
Junction temperature T
J
-- 4 0 105 °C