Datasheet
Loop Compensation
2
1
1 2
2 2
OUT (max) OUT SENSE
IN _ RMS FQ
I V R K
M M
V Kh
=
(76)
1
FQ
SW ( typ )
K
f
=
(77)
1
15 385
65
FQ
K . s
kHz
m= =
(78)
1
7K =
(79)
2
1 2
2 2
0 9 391 0 067 7
0 374
0 92 115 15 385m m
´ ´ W´
= =
´ ´
. A V . V
M M .
. V . s s
(80)
VCOMP - V
0
0.4
0.8
1.2
1.6
2.0
M
1
M
2
M
1
M
2
vs
VCOMP
0.2
0.6
1.0
1.4
1.8
0 1 2 5 73 4 6
UCC28019A
SLUS828B – DECEMBER 2008 – REVISED APRIL 2009 ..................................................................................................................................................
www.ti.com
The selection of compensation components, for both the current loop and the voltage loop, is made easier by
using the UCC28019A Design Calculator spreadsheet that can be found in the Tools section of the UCC28019A
product folder on the Texas Instruments website. The current loop is compensated first by determining the
product of the internal loop variables, M
1
M
2
, using the internal controller constants K
1
and K
FQ
:
The VCOMP operating point is found on Figure 29 . The Design Calculator spreadsheet enables the user to
iteratively select the appropriate VCOMP value.
Figure 29. M
1
M
2
vs. VCOMP
For the given M
1
M
2
of 0.374 V/ µ s, the VCOMP is approximately equal to 4, as shown in Figure 29 .
32 Submit Documentation Feedback Copyright © 2008 – 2009, Texas Instruments Incorporated
Product Folder Link(s): UCC28019A