Datasheet

UCC27511
UCC27512
SLUSAW9E FEBRUARY 2012REVISED DECEMBER 2013
www.ti.com
ABSOLUTE MAXIMUM RATINGS
(1)(2)(3)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Supply voltage range VDD -0.3 20
OUTH voltage, (UCC27511) -0.3 VDD + 0.3
DC -0.3 20
OUTL voltage, (UCC27511) V
Repetitive pulse less than 200 ns
(4)
-2 20
DC -0.3 VDD + 0.3
OUT voltage, (UCC27512)
Repetitive pulse less than 200 ns
(4)
-2 VDD + 0.3
I
OUT_DC
(source) 0.3
Output continuous current
(OUTH source current and OUTL sink current)
I
OUT_DC
(sink) 0.6
A
I
OUT_pulsed
(source) 4
Output pulsed current (0.5 µs)
(OUTH source current and OUTL sink current)
I
OUT_pulsed
(sink) 8
IN+, IN-
(5)
-0.3 20
Human Body Model, HBM 4000 V
ESD
Charged Device Model, CDM 1000
Operating virtual junction temperature range, T
J
-40 150
Storage temperature range, T
STG
-65 150
°C
Soldering, 10 sec. 300
Lead temperature
Reflow 260
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND unless otherwise noted. Currents are positive into and negative out of the specified terminal. See
Packaging Section of the datasheet for thermal limitations and considerations of packages.
(3) These devices are sensitive to electrostatic discharge; follow proper device handling procedures.
(4) Values are verified by characterization on bench.
(5) Maximum voltage on input pins is not restricted by the voltage on the VDD pin.
4 Submit Documentation Feedback Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: UCC27511 UCC27512