Datasheet
UCC27210
UCC27211
www.ti.com
SLUSAT7E –NOVEMBER 2011–REVISED AUGUST 2013
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Supply voltage range, V
DD
(1)
, V
HB
- V
HS
-0.3 20
Input voltages on LI and HI, V
LI
, V
HI
-10 20
DC -0.3 V
DD
+ 0.3
Output voltage on LO, V
LO
Repetitive pulse <100 ns
(2)
-2 V
DD
+ 0.3
DC V
HS
– 0.3 V
HB
+ 0.3 V
Output voltage on HO, V
HO
Repetitive pulse <100 ns
(2)
V
HS
- 2 V
HB
+ 0.3
DC -1 115
Voltage on HS, V
HS
Repetitive pulse <100 ns
(2)
-(24V-VDD) 115
Voltage on HB, V
HB
-0.3 120
Human Body Model (HBM) 2
ESD kV
Field Induced Charged Device Model
1
(FICDM)
Operating virtual junction temperature range, T
J
-40 150
Storage temperature, T
STG
-65 150 °C
Lead temperature (soldering, 10 sec.) 300
(1) All voltages are with respect to VSS unless otherwise noted. Currents are positive into, negative out of the specified terminal.
(2) Verified at bench characterization. VDD is the value used in an application design.
RECOMMENDED OPERATING CONDITIONS
all voltages are with respect to V
SS
; currents are positive into and negative out of the specified terminal. –40°C < T
J
= T
A
<
140°C (unless otherwise noted)
PARAMETER MIN TYP MAX UNIT
Supply voltage range, V
DD
, V
HB
-V
HS
8 12 17
Voltage on HS, V
HS
-1 105
V
Voltage on HS, V
HS
(repetitive pulse <100 ns) -(24V-VDD) 110
V
HS
+8, V
HS
+17,
Voltage on HB, V
HB
V
DD
–1 115
Voltage slew rate on HS 50 V/ns
Operating junction temperature range -40 140 °C
Copyright © 2011–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: UCC27210 UCC27211