Datasheet

UCC27200A, UCC27201A
www.ti.com
SLUSAF9A FEBRUARY 2011 REVISED DECEMBER 2011
DEVICE RATINGS
ABSOLUTE MAXIMUM RATINGS
Over operating free-air temperature, unless noted, all voltages are with respect to V
SS
(1)
PARAMETER VALUE UNIT
Supply voltage range,
(2)
V
DD
-0.3 to 20
Input voltages on LI and HI, V
LI
, V
HI
-0.3 to 20
DC -0.3 to V
DD
+ 0.3,
Output voltage on LO, V
LO
Repetitive pulse <100 ns
(3)
-2 to V
DD
+ 0.3
DC V
HS
0.3 to V
HB
+ 0.3
Output voltage on HO, V
HO
V
Repetitive pulse <100 ns
(3)
V
HS
- 2 to V
HB
+ 0.3, (V
HB
- V
HS
<20)
DC -1 to 120
Voltage on HS, V
HS
Repetitive pulse <100 ns
(3)
-18 to 120
Voltage on HB, V
HB
-0.3 to 120
Voltage On HB-HS -0.3 to 20
Operating virtual junction temperature range, T
J
-40 to +150
Storage temperature, T
STG
-65 to +150 °C
Lead temperature (soldering, 10 sec.) +300
Power dissipation at T
A
= 25°C (D package)
(4)
1.3
Power dissipation at T
A
= 25°C (DDA package)
(4)
2.7
W
Power dissipation at T
A
= 25°C (DRM package)
(4)
3.3
Power dissipation at T
A
= 25°C (DRC package)
(4)
2.86
Human body model 2000
V
CDM 1000
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to V
ss
. Currents are positive into, negative out of the specified terminal.
(3) Values are verified by characterization and are not production tested.
(4) This data was taken using the JEDEC proposed high-K test PCB. See the THERMAL CHARACTERISTICS section for details.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
PARAMETER MIN NOM MAX UNIT
V
DD
Supply voltage range 8 12 17
V
HS
Voltage on HS -1 105
V
Voltage on HS, (repetitive pulse <100 ns) -15 110
V
HB
V
HS
+ 8, V
HS
+ 17,
Voltage on HB
V
DD
1 115
Voltage slew rate on HS 50 V / ns
T
J
Operating junction temperature range -40 +140 °C
Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): UCC27200A UCC27201A