Datasheet

Electrical Performance
www.ti.com
3 Electrical Performance
Table 1. Electrical Performance
(1)(2)(3)
PARAMETER CONDITIONS MIN TYP MAX UNITS
INPUT CHARACTERISTIC
V
I
Input Voltage 108 265 V
rms
F Line frequency 48 65 Hz
I
I
Input current 8 A
rms
p.f. Power factor 0.95
OUTPUT CHARACTERISTIC
PFC Stage:
V
o(HVDC)
Output voltage 390 V
dc
LLC resonant stage:
V
I(HVDC)
Input voltage 330 410 V
dc
V
o
Output voltage 50
I
o
Output current 1 12 A
I
o, peak
Peak output current 20
P
o
Output power Continuously 250 W
Maximum for 5min 600
Peak 20mS 1000
I
LIM
Current limit 26 A
P
LIM
Power limit 700 W
di/dt Output current slew rate Do not exceed maximum slew rate 11 A
200 ms
SYSTEM CHARACTERISTIC
η Full load efficiency 110 V
ac
, 80% load 88%
η Nom load efficiency 230 V
ac
, 50% load 91%
t
HOLD
Hold-up time Nominal V
I
, 20% load 20 ms
OV
THLD
Over-voltage threshold OV shutdown and restart 55 V
Temperature range National Conv airflow 0 50 °C
(1)
Operates down to zero load with reduced regulation.
(2)
Forced Air cooling can be needed depending on the housing in which the SMPS is used – the temperature warning open drain
output signal can be used to control a fan.
(3)
The 50-V output will not power up, unless the ±15-V outputs are loaded. It is recommended that you load these outputs with 75
Ω during power up.