5.3 List of Test Points
Table 2. Test Point Functions
TEST POINTS NAME DESCRIPTION
TP1 PGND Input voltage negative test point, for efficiency test
TP2 Vin+ Input voltage positive test point, for efficiency test
TP3 Bias_P1 Primary bias, 9V.
TP4 VOUT+ Output voltage positive test point for efficiency
TP5 VOUT- Output voltage negative test point for efficiency
TP6 Loop+ Feedback loop injection for UCC25230
TP7 Loop+ Feedback loop injection for UCC28250
TP8 Loop- Feedback loop injection for UCC28250
TP9 Loop- Primary side signal ground
TP10 Prebias+ Prebias output positive input
TP11 Vo_Ripple Output voltage ripple test
TP12 Bias_P Primary bias, 9 V
TP13 Bias_S Secondary bias, 8 V
J1 INPUT Input voltage terminals
J2 OUTPUT Output voltage terminals
6
Biased Half-Bridge Converter with UCC28250 Secondary-Side Control for 48-V SLUU863–February 2012
Telecom Applications
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated