6.4 Output Voltage Ripple
1. Expose the ground barrel of the scope probe. Insert the tip of the probe into the plated via located on
the V
OUT
+ pad of the EVM (TP1) and lean the probe so that the exposed ground barrel is resting on the
test point on the Vout- pad of the EVM (TP3) for a tip and barrel measurement as shown in the
example depicted in Figure 4.
2. Apply power to the EVM per Section 6.1.
3. Monitor the output voltage ripple on the oscilloscope.
Figure 4. Typical Example of Tip and Barrel Measurement Technique
NOTE: This photo was not taken on the UCC24610EVM specifically but serves as a visual aid to
perform the test measurement.
6.5 Equipment Shutdown
1. Ensure the load is at maximum of 5 A; this will quickly discharge the output capacitors.
2. Turn off the AC source.
12
5-V, 25-W Flyback Converter With Secondary-Side Synchronous Rectification SLUU434August 2010
Copyright © 2010, Texas Instruments Incorporated