Datasheet
3
UC1710
UC2710
UC3710
ELECTRICAL CHARACTERISTICS:
Unless otherwise stated, these specifications apply for V
IN
= V
C
= 15V, No load,
T
A
= T
J.
PARAMETERS TEST CONDITIONS MIN TYP MAX UNITS
UVLO Threshold Hysteresis 0.1 0.3 0.5 V
Digital Input Low Level 0.8 V
Digital Input High Level 2.0 V
Digital Input Current Digital Input = 0.0V –70 –4.0 µA
Output High Sat., V
C
– V
O
I
O
= –100mA 1.35 2.2 V
I
O
= –6A 3.2 4.5 V
Output Low Sat., V
O
I
O
= 100mA 0.25 0.6 V
I
O
= 6A 3.4 4.5 V
Thermal Shutdown 165 °C
From Inv., Input to Output (Note 3, 4):
Rise Time Delay CL = 0 35 70 ns
CL = 2.2nF 35 70 ns
CL = 30nF 35 70 ns
10% to 90% Rise CL = 0 20 40 ns
CL = 2.2nF 25 40 ns
CL = 30nF 85 150 ns
Fall Time Delay CL = 0 35 70 ns
CL = 2.2nF 35 70 ns
CL = 30nF 35 80 ns
90% to 10% Fall CL = 0 15 40 ns
CL = 2.2nF 20 40 ns
CL = 30nF 85 150 ns
From N.I. Input to Output (Note 3,4):
Rise Time Delay CL = 0 35 70 ns
CL = 2.2nF 35 70 ns
CL = 30nF 35 70 ns
10% to 90% Rise CL = 0 20 40 ns
CL = 2.2nF 25 40 ns
CL = 30nF 85 150 ns
Fall Time Delay CL = 0 35 70 ns
CL = 2.2nF 35 70 ns
CL = 30nF 35 80 ns
90% to 10% Fall CL = 0 15 40 ns
CL = 2.2nF 20 50 ns
CL = 30nF 85 150 ns
Total Supply Current at 200kHz Input
Switching Frequency
T
A
= 25°C (Note 5) CL = 0 30 40 mA
Note: 3. Delay measured from 50% input change to 10% output change.
Note: 4. Those parameters with CL = 30nF are not tested in production.
Note: 5. Inv. Input pulsed at 50% duty cycle with N.I. Input = 3V. or N.I. Input pulsed at 50% duty cycle with Inv. Input = 0V.
UNITRODE CORPORATION
7 CONTINENTAL BLVD. • MERRIMACK, NH 03054
TEL. (603) 424-2410 FAX (603) 424-3460