Datasheet

TXS0206
SCES697C AUGUST 2009REVISED JANUARY 2010
www.ti.com
ELECTRICAL CHARACTERISTICS
Level Translator
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CCA
V
CCB
MIN TYP
(1)
MAX UNIT
I
OH
= –100 μA 1.1 V to 3.6 V V
CCA
* 0.8
I
OH
= –0.5 mA 1.1 V 0.8
I
OH
= –1 mA 1.4 V 1.05
A port
(CLK-f output)
I
OH
= –2 mA 1.65 V 1.2
V
OH
1.1 V to 3.6 V V
I
OH
= –4 mA 2.3 V 1.75
I
OH
= –8 mA 3 V 2.3
A port
(DAT and CMD I
OH
= –20 μA 1.1 V to 3.6 V V
CCA
× 0.8
outputs)
I
OL
= 100 μA 1.1 V to 3.6 V V
CCA
× 0.8
I
OL
= 0.5 mA 1.1 V 0.35
I
OL
= 1 mA 1.4 V 0.35
A port
1.1 V to 3.6 V V
(CLK-f output)
I
OL
= 2 mA 1.65 V 0.45
I
OL
= 4 mA 2.3 V 0.55
V
OL
I
OL
= 8 mA 3 V 0.7
I
OL
= 135 μA 0.4
I
OL
= 180 μA 0.4
A port
(DAT and CMD I
OL
= 220 μA 1.1 V to 3.6 V 0.4 V
outputs)
I
OL
= 300 μA 0.4
I
OL
= 400 μA 0.55
I
OH
= –100 μA 1.1 V to 3.6 V V
CCA
× 0.8
I
OH
= –0.5 mA 1.1 V 0.8
I
OH
= –1 mA 1.4 V 1.05
B port
(CLK output)
I
OH
= –2 mA 1.65 V 1.2
V
OH
1.1 V to 3.6 V V
I
OH
= –4 mA 2.3 V 1.75
I
OH
= –8 mA 3 V 2.3
B port
I
OH
= –20 μA 1.1 V to 3.6 V V
CCA
× 0.8
(DAT output)
(1) All typical values are at T
A
= 25°C.
10 Submit Documentation Feedback Copyright © 2009–2010, Texas Instruments Incorporated
Product Folder Link(s): TXS0206