ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CCA
Supply voltage range –0.5 4.6 V
V
CCB
Supply voltage range –0.5 4.6 V
I/O ports (A port) –0.5 4.6
V
I
Input voltage range I/O ports (B port) –0.5 4.6 V
Control inputs –0.5 4.6
A port –0.5 4.6
Voltage range applied to any output in the high-impedance or power-off
V
O
V
state
(2)
B port –0.5 4.6
A port –0.5 4.6
V
O
Voltage range applied to any output in the high or low state
(2)
V
B port –0.5 4.6
I
IK
Input clamp current V
I
< 0 –50 mA
I
OK
Output clamp current V
O
< 0 –50 mA
I
O
Continuous output current ±50 mA
Continuous current through V
CCA
, V
CCB
, or GND ±100 mA
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
THERMAL IMPEDANCE RATINGS
UNIT
ZQC package 171.6
θ
JA
Package thermal impedance
(1)
°C/W
YFF package 75
(1) The package thermal impedance is calculated in accordance with JESD 51-7.
6 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TWL1200