7.2.24 Vertical Blanking Start Register
Address 18h
Default 00h
7 6 5 4 3 2 1 0
Vertical blanking start
Vertical blanking (VBLK) start:
0111 1111 = 127 lines after start of vertical blanking interval
0000 0001 = 1 line after start of vertical blanking interval
0000 0000 = Same time as start of vertical blanking interval (default) (see Figure 3-4, Figure 3-5, and Figure 3-6)
1111 1111 = 1 line before start of vertical blanking interval
1000 0000 = 128 lines before start of vertical blanking interval
Vertical blanking is adjustable with respect to the standard vertical blanking intervals. The setting in this
register determines the timing of the GPCL/VBLK signal when it is configured to output vertical blank (see
register 03h). The setting in this register also determines the duration of the luma bypass function (see
register 07h).
7.2.25 Vertical Blanking Stop Register
Address 19h
Default 00h
7 6 5 4 3 2 1 0
Vertical blanking stop
Vertical blanking (VBLK) stop:
0111 1111 = 127 lines after stop of vertical blanking interval
0000 0001 = 1 line after stop of vertical blanking interval
0000 0000 = Same time as stop of vertical blanking interval (default) (see Figure 3-4, Figure 3-5, and Figure 3-6)
1111 1111 = 1 line before stop of vertical blanking interval
1000 0000 = 128 lines before stop of vertical blanking interval
Vertical blanking is adjustable with respect to the standard vertical blanking intervals. The setting in this
register determines the timing of the GPCL/VBLK signal when it is configured to output vertical blank (see
register 03h). The setting in this register also determines the duration of the luma bypass function (see
register 07h).