7.2.23 Ancillary SAV/EAV Control
Address 17h
Default 52h
7 6 5 4 3 2 1 0
Reserved Scaler PD Include scale Include scale Include scale Include unscale Include Include unscale
ancillary SAV EAV ancillary unscale SAV EAV
Include unscaled EAV:
0 = AVID period does not include the EAV sync codes (default).
1 = AVID period includes the EAV sync codes.
Include unscaled SAV:
0 = AVID period does not include the SAV sync codes.
1 = AVID period includes the SAV sync codes (default).
Include unscaled ancillary data:
0 = AVID period includes the ancillary data region (default).
1 = AVID period does not include the ancillary data region.
Include scaled EAV:
0 = AVID period does not include the EAV sync codes (default).
1 = AVID period includes the EAV sync codes.
Include scaled SAV:
0 = AVID period does not include the SAV sync codes.
1 = AVID period includes the SAV sync codes (default).
Include scaled ancillary data:
0 = AVID period includes the ancillary data region (default).
1 = AVID period does not include the ancillary data region.
Scaler PD (scaler power down):
0 = Scaler active
1 = Scaler powered down (default)
42 Internal Control Registers Copyright © 2007–2010, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TVP5154A