Functional Description
30
May 2006SLES043A
3.22.12 Hue Control Register
Address 0Bh
7 6 5 4 3 2 1 0
Hue control
Hue control:
0111 1111 = +180 degrees
0000 0000 = 0 degrees (default)
1000 0000 = −180 degrees
3.22.13 Contrast Control Register
Address 0Ch
7 6 5 4 3 2 1 0
Contrast control
Contrast control:
1111 1111 = 255 (maximum contrast)
1000 0000 = 128 (default)
0000 0000 = 0 (minimum contrast)
3.22.14 Outputs and Data Rates Select Register
Address 0Dh
7 6 5 4 3 2 1 0
Reserved YUV output code range UV code format YUV data path bypass YUV output format
YUV output code range:
0 = ITU−R BT.601 coding range (Y ranges from 16 to 235. U and V range from 16 to 240)
1 = Extended coding range (Y, U, and V range from 1 to 254) (default)
UV code format:
0 = Offset binary code (2s complement + 128) (default)
1 = Straight binary code (2s complement)
YUV data path bypass:
00 = Normal operation (default)
01 = Digital composite output pins connected to decimation filter output, decoder function bypassed,
data output alternately as Y and UV buses at the SCLK rate.
10 = YUV output pins connected to A/D output, decoder function bypassed, data output at SCLK rate.
11 = Reserved
YUV output format
:
000 = 8-bit 4:2:2 YUV with discrete sync output
001 = Reserved
010 = Reserved
011 = Reserved
100 = Reserved
101 = Reserved
110 = Reserved
111 = 8-bit ITU−R BT.656 interface with embedded sync output (default)