Datasheet

3−3
3.3.3 Timing
3.3.3.1 Clocks, Video Data, Sync Timing
PARAMETER
TEST CONDITIONS
(see NOTE 2)
MIN TYP MAX UNIT
Duty cycle PCLK 40% 50% 60%
t
1
PCLK high time 18.5 ns
t
2
PCLK low time 18.5 ns
t
3
PCLK fall time 10% to 90% 4 ns
t
4
PCLK rise time 90% to 10% 4 ns
t
5
Output hold time 2 ns
t
6
Output delay time 3 8 ns
NOTE 2: Measured with a load of 15 pF.
V
OH
Y, C, AVID,
VS, HS, FID
V
OL
Valid DataValid Data
PCLK
t
3
t
1
t
2
t
5
t
6
t
4
Figure 3−1. Clocks, Video Data, and Sync Timing