Table 2-119. VDP General Line Mode and Line Address Register
Subaddress 80 0600h – 80 0611h
(default line mode = FFh, line address = 00h)
Subaddress 7 6 5 4 3 2 1 0
80 0600h Line address 1
80 0601h Line mode 1
80 0602h Line address 2
80 0603h Line mode 2
80 0604h Line address 3
80 0605h Line mode 3
80 0606h Line address 4
80 0607h Line mode 4
80 0608h Line address 5
80 0609h Line mode 5
80 060Ah Line address 6
80 060Bh Line mode 6
80 060Ch Line address 7
80 060Dh Line mode 7
80 060Eh Line address 8
80 060Fh Line mode 8
80 0610h Line address 9
80 0611h Line mode 9
Line address [7:0]: Line number to process selected line mode register on
Line mode x [7:0]
Bit 7
0 = Disabled filters
1 = Enabled filters for teletext and CC (null byte filter) (default)
Bit 6
0 = Send sliced VBI data to registers only
1 = Send sliced VBI data to FIFO and registers, teletext data only goes to FIFO (default)
Bit 5
0 = Allow VBI data with errors in the FIFO
1 = Do not allow VBI data with errors in the FIFO (default)
Bit 4
0 = Disabled error detection and correction
1 = Enabled error detection and correction (teletext only) (default)
Bit 3
0 = Field 1
1 = Field 2 (default)
Bit [2:0]
000 = Teletext (WST625, Chinese Teletext, NABTS 525)
001 = CC (US, European, Japan, China)
010 = WSS (525, 625)
011 = VITC
100 = VPS/PDC (PAL only), Gemstar (NTSC only)
101 = USER 1
110 = USER 2
111 = Reserved (active video) (default)