Datasheet

TVP5147M1
SLES140G JULY 2005REVISED FEBRUARY 2012
www.ti.com
The following register writes must be made before normal operation of the device.
I
2
C I
2
C
STEP
SUBADDRESS DATA
1 0x03 0x01
2 0x03 0x00
When using any industrial temperature range device (TVP5147M1IPFP and TVP5147M1IPFPQ1), the
following I
2
C register writes must be executed following device power up and RESETB to properly initialize
VBUS register 0xA00014. When patch code is being used, these I
2
C writes must be executed after the
patch code has been loaded.
NOTE
The following I
2
C writes are mandatory for industrial temperature range devices but are
optional for commercial temperature range devices (TVP5147M1PFP).
I
2
C I
2
C
STEP
SUBADDRESS DATA
1 0xE8 0x14
2 0xE9 0x00
3 0xEA 0xA0
4 0xE0 0x14
2.9 Adjusting External Syncs
The proper sequence to program the following external syncs is:
To set NTSC, PAL-M, NTSC 443, PAL60 (525-line modes):
Set the video standard to NTSC (register 02h).
Set HSYNC, VSYNC, VBLK, and AVID external syncs (registers 16h through 24h).
To set PAL, PAL-N, SECAM (625-line modes):
Set the video standard to PAL (register 02h).
Set HSYNC, VSYNC, VBLK, and AVID external syncs (registers 16h through 24h).
For autoswitch, set the video standard to autoswitch (register 02h).
36 Functional Description Copyright © 2005–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TVP5147M1