Datasheet
TVP5147M1
SLES140G –JULY 2005–REVISED FEBRUARY 2012
www.ti.com
The following register writes must be made before normal operation of the device.
I
2
C I
2
C
STEP
SUBADDRESS DATA
1 0x03 0x01
2 0x03 0x00
When using any industrial temperature range device (TVP5147M1IPFP and TVP5147M1IPFPQ1), the
following I
2
C register writes must be executed following device power up and RESETB to properly initialize
VBUS register 0xA00014. When patch code is being used, these I
2
C writes must be executed after the
patch code has been loaded.
NOTE
The following I
2
C writes are mandatory for industrial temperature range devices but are
optional for commercial temperature range devices (TVP5147M1PFP).
I
2
C I
2
C
STEP
SUBADDRESS DATA
1 0xE8 0x14
2 0xE9 0x00
3 0xEA 0xA0
4 0xE0 0x14
2.9 Adjusting External Syncs
The proper sequence to program the following external syncs is:
• To set NTSC, PAL-M, NTSC 443, PAL60 (525-line modes):
– Set the video standard to NTSC (register 02h).
– Set HSYNC, VSYNC, VBLK, and AVID external syncs (registers 16h through 24h).
• To set PAL, PAL-N, SECAM (625-line modes):
– Set the video standard to PAL (register 02h).
– Set HSYNC, VSYNC, VBLK, and AVID external syncs (registers 16h through 24h).
• For autoswitch, set the video standard to autoswitch (register 02h).
36 Functional Description Copyright © 2005–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TVP5147M1