74
SLES084C − August 2007TVP5146
2.11.83 Interrupt Status 1 Register
Subaddress F3h
Read only
7 6 5 4 3 2 1 0
Reserved Macrovsion status changed Standard changed FIFO full
Macrovision status changed: Macrovision status changed masked
0 = Macrovision status not changed
1 = Macrovision status changed
Standard changed: Standard changed masked
0 = Video standard not changed
1 = Video standard changed
FIFO full: Full status of FIFO masked
0 = FIFO not full
1 = FIFO was full during write to FIFO, see the interrupt mask 1 register at subaddress F5h for details (see
Section 2.11.85)