6 ELECTRICAL SPECIFICATIONS
6.1 ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
VALUE UNIT
V
DD33
-0.3 to 3.8
Steady-state supply voltage V
V
DD11
-0.3 to 1.4
USB 2.0 DP/DM -0.3 to VDD33 + 0.3 ≤ 3.8
SuperSpeed USB TXP/M and RXP/M -0.3 to VDD33 + 0.3 ≤ 3.8
V
IO
V
XI/XO -0.3 to 1.98
3.3-V Tolerant I/O -0.3 to VDD33 + 0.3 ≤ 3.8
V
USB_VBUS
-0.3 to 1.2 V
T
stg
Storage temperature range -65 to 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Expose to absolute-maximum-rated conditions for extended periods may affect device reliability
6.2 RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN NOM MAX UNIT
V
DD33
3 3.3 3.6
Steady-state supply voltage V
V
DD11
(1)
0.99 1.1 1.26
USB 2.0 DP/DM 0 VDD33
SuperSpeed USB TXP/M and RXP/M 0 VDD33
V
IO
V
XI/XO 0 1.8
3.3-V Tolerant I/O 0 VDD33
V
USB_VBUS
0 1.155 V
T
A
Operating free-air temperature range 0 25 70 °C
T
J
Operating junction temperature range 0 25 105 °C
(1) A 1.05-V supply may be used as long as minimum supply conditions are met.