Datasheet
www.ti.com
3 Specifications
3.1 Absolute Maximum Ratings
(1)
3.2 Commercial Operating Conditions
3.3 Electrical Characteristics
TUSB3210
Universal Serial Bus
General-Purpose Device Controller
SLLS466F – FEBRUARY 2001 – REVISED AUGUST 2007
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage –0.5 4 V
V
I
Input voltage –0.5 V
CC
+ 0.5 V
V
O
Output voltage –0.5 V
CC
+ 0.5 V
I
IK
Input clamp current ± 20 mA
I
OK
Output clamp current ± 20 mA
Storage temperature –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
PARAMETER MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
V
I
Input voltage 0 V
CC
V
V
IH
High-level input voltage 2 V
CC
V
V
IL
Low-level input voltage 0 0.8 V
T
A
Operating temperature 0 70 ° C
T
A
= 25 ° C, V
CC
= 3.3 V ± 0.3 V, GND = 0 V
PARAMETER TEST CONDITIONS MIN NOM MAX UNIT
V
OH
High-level output voltage I
OH
= –4 mA V
CC
– 0.5 V
V
OL
Low-level output voltage I
OL
= 4 mA 0.5 V
V
IT+
Positive input threshold voltage V
I
= V
IH
2 V
V
IT–
Negative input threshold voltage V
I
= V
IL
0.8 V
V
hys
Hysteresis (V
IT+
– V
IT–
) V
I
= V
IH
1 V
I
IH
High-level input current V
I
= V
IH
± 1 μ A
I
IL
Low-level input current V
I
= V
IL
± 1 μ A
I
OZ
Output leakage current (Hi-Z) V
I
= V
CC
or V
SS
10 μ A
C
I
Input capacitance 5 pF
C
O
Output capacitance 7 pF
I
CC
Quiescent 25 45 mA
I
CCx
Suspend 45 μ A
I
CCx1.8
Suspend 1.8 VDD 1 μ A
Submit Documentation Feedback Specifications 39