6.5.8 Power State Transition Time
The P1 to P0 transition time is the amount of time for the TUSB1310A to return to P0 state, after having
been in the P1 state. This time is measured from when the MAC sets the POWER_DOWN signals to P0
until the TUSB1310A asserts PHY_STATUS. The TUSB1310A asserts PHY_STATUS when it is ready to
begin data transmission and reception.
The P2 to P0 transition time is the amount of time for the TUSB1310A to return to the P0 state, after
having been in the P2 state. This time is measured from when the MAC sets the POWER_DOWN signals
to P0 until the TUSB1310A asserts PHY_STATUS. The TUSB1310A asserts PHY_STATUS when it is
ready to begin data transmission and reception.
The P3 to P0 transition time is the amount of time for the TUSB1310A to go to P0 state, after having been
in the P3 state. Time is measured from when the MAC sets the POWER_DOWN signals to P0 until the
TUSB1310A deasserts PHY_STATUS. The TUSB1310A asserts PHY_STATUS when it is ready to begin
data transmission and reception.