Datasheet

Test Point
D.U.T.
V
+
33 Ω 500 Ω
50 pF
MBL142
Test Point
D.U.T.
MGS968
25 pF
Test Point
D.U.T.
D+/D–
1.5 kΩ
15 kΩ
33 Ω
V
PU(3.3)
C
L
TUSB1105, TUSB1106
www.ti.com
SCAS818E MAY 2006REVISED SEPTEMBER 2010
APPLICATION INFORMATION
Figure 5. Load for Enable and Disable Times
A. V = 0 V for t
PZH
, t
PHZ
B. V = V
reg(3.3)
for t
PZL
, t
PLZ
Figure 6. Load for VM, VP, and RCV
Figure 7. Load for D+, D–
A. Full-speed mode: connected to D+
B. Low-speed mode: Connected to D–
C. Load capacitance:
C
L
= 50 pF or 125 pF (full-speed mode, minimum or maximum timing)
C
L
= 200 pF or 600 pF (low-speed mode, minimum or maximum timing)
A. Only for TUSB1105
Copyright © 2006–2010, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Link(s): TUSB1105 TUSB1106