Datasheet

-70
-68
-66
-64
-62
-60
-58
-56
-54
-52
-50
1 10 100
f-Frequency-MHz
Gain-dB
www.ti.com
Demonstration Kit Test Configuration
The input of the TSW7001 is by default terminated with a 50- to ground to enable a connection to a 50-
signal source.
Typical IMD3 and harmonic distortion data was obtained for the default case of 40-dB gain (Rf=402,
Rg=18) driving 100 at the output of the TSW7001 (50- source into 50- spectrum analyzer).
Figure 11. IMD3 Plot for TSW7001 at 10 MHz
Figure 12. IMD3 for TSW7001 in 40-dB Gain Mode
SLWU058 August 2008 Voltage-Controlled Amplifier Evaluation Kit 13
Submit Documentation Feedback