Datasheet

Software Control
www.ti.com
2.2.1 LMK04800 Main Tab
After starting the GUI, the LMK04800 Main tab is selected by default and the display looks as shown in
Figure 2.
Figure 2. LMK04800 Main Tab Window
If the GUI connects to the board properly, the USB Status indicator turns green. If the indicator is not
bright green (as shown in Figure 2), check that the board is powered up and the USB cable is installed.
Press the Reset USB button a few times. If this still does not establish the connection, cycle power to the
board and host PC. If this still does not correct the problem, make sure the USB drivers were installed
properly using the Device Manager tool on the PC.
Table 2. Main Window Description
Section Description
Reset USB Issues a software reset to the FTDI USB controller.
Send All Sends all current displayed GUI values to the LMK internal registers.
Save Saves all of the current displayed GUI values to a file.
Load Opens a browser for loading a custom register file into the GUI. The values are not loaded into
the LMK until the Send All button is clicked.
Read All Currently not used.
EXIT Closes the GUI
EEPROM
(1)
Writes and reads the GUI register values to the on-board EEPROM. The writable address range
is from 8 to 15. The readable range is from 0 to 15. Addresses 0-7 are factory programmed and
read only.
LMK04800 Registers Displays the address and data values of the LMK.
(1)
The EEPROM Read only works properly with the Windows 7 OS by opening the GUI using the Run as Administrator option.
4
TSW4806EVM SLAU454July 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated