Datasheet
Measurements
www.ti.com
3.1 Expected Values
Table 2 and Table 3 outline the expected values for certain test points on the board to monitor the
functionality of the TSW2110. Depending on the input voltage configuration on the board, some of the
expected values are different. The charge pump draws more current in the 3.3-V input configuration than
the LDO regulator does with the 5-V input.
Table 2. Expected Values With a 5-V Input
System Current 115 mA
Input Voltage 5 V
Amplifier Voltage 4.98 V
Table 3. Expected Values With a 3.3-V Input
System Current 190 mA
Input Voltage 3.3 V
Amplifier Voltage 5.01 V
3.2 Output Waveform
Figure 4. Capture on TSW1400 of the ADS4249EVM, Input Signal Source Is TSW2110
The data captured meets datasheet-type performance for the ADS4249EVM.
4
TSW2110EVM Evaluation Module (EVM) SLAU438–March 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated