X, Y, Z1, Z2, BAT, AUX1, AUX2, TEMP1 and TEMP2 Registers
The results of all ADC conversions are placed in the appropriate data register. The data format of the result
word, R, of these registers is right-justified, as follows:
Bit 15
MSB
Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
LSB
0 0 0 0 R11
MSB
R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 R0
LSB
PAGE 1 CONTROL REGISTER MAP
REGISTER 00H: Touch-Screen ADC Control
BIT NAME
RESET
VALUE
READ/
WRITE
FUNCTION
D15 PSTCM 0 R/W Pen Status/Control Mode.
READ
0 => There is no screen touch (default).
1 => The pen is down
WRITE
0 => Host controlled touch screen conversions (default).
1 => The TSC2101 controlled touch screen conversions.
D14 ADST 1(for read)
0 (for write)
R/W ADC STATUS.
READ
0 =>ADC is busy
1 => ADC is not busy (default).
WRITE
0 => Normal mode (default).
1 => Stop conversion and power down.
D13D10 ADCSM 0000 R/W ADC Scan Mode.
0000 => No scan
0001 => Touch screen scan function: X and Y coordinates are converted and the results returned
to X and Y data registers. Scan continues until either the pen is lifted or a stop bit is
sent.
0010 => Touch screen scan function: X, Y, Z1 and Z2 coordinates are converted and the results
returned to X, Y, Z1 and Z2 data registers. Scan continues until either the pen is lifted
or a stop bit is sent.
0011 => Touch screen scan function: X coordinate is converted and the results returned to X data
register.
0100 => Touch screen scan function: Y coordinate is converted and the results returned to Y data
register.
0101 => Touch screen scan function: Z1 and Z2 coordinates are converted and the results
returned to Z1 and Z2 data registers
0110 => BAT input is converted and the results returned to the BAT data register.
0111 => AUX2 input is converted and the results returned to the AUX2 data register
1000 => AUX1 input is converted and the results returned to the AUX1 data register.
1001 => Auto Scan function: For AUX1, AUX2, TEMP1 or TEMP2 as chosen using control
register 0CH/page 1. Scan continues until stop bit is sent or D13D10 are changed.
1010 => TEMP1 input is converted and the results returned to the TEMP1 data register.
1011 => Port scan function: BAT, AUX1, AUX2 inputs are measured and the results returned to
the appropriate data registers.
1100 => TEMP2 input is converted and the results returned to the TEMP2 data register.
1101 => Turn on X+, X drivers
1110 => Turn on Y+, Y drivers
1111 => Turn on Y+, X drivers
D9D8 RESOL 00 R/W Resolution Control. The ADC resolution is specified with these bits.
00 => 12-bit resolution
01 => 8-bit resolution
10 => 10-bit resolution
11 => 12-bit resolution