Datasheet

TSC2101
SLAS392D JUNE 2003 REVISED MAY 2005
www.ti.com
12
th
(WS)
ts
(WS)
ts
(DI)
th
(DI)
td
(DOBCLK)
td
(DOWS)
WCLK
BCLK
SDOUT
SDIN
tL(BCLK)
tH(BCLK)
tP(BCLK)
Figure 3. I
2
S/LJF/RJF Timing in Slave Mode
Typical Timing Requirements (see Figure 3)
PARAMETER
(1)
IOVDD = 1.1 V IOVDD = 3.3 V
UNITS
PARAMETER
(1)
MIN MAX MIN MAX
UNITS
t
H
(BCLK) BCLK high period 40 35 ns
t
L
(BCLK) BCLK low period 40 35 ns
t
s
(WS) WCLK setup 6 6 ns
t
h
(WS) WCLK hold 6 6 ns
t
d
(DOWS) WCLK to DOUT delay (for LJF mode) 30 18 ns
t
d
(DOBCLK) BCLK to DOUT delay 30 15 ns
t
s
(DI) SDIN setup 6 6 ns
t
h
(DI) SDIN hold 6 6 ns
t
r
Rise time 5 4 ns
t
r
Fall time 5 4 ns
(1)
These parameters are based on characterization and are not tested in production.