Datasheet

www.ti.com
t
COORDINATE
+
OH2
f
OSC
)3 @
ǒ
t
PVS
)t
PRE
)t
SNS
)
OH
DLY1
f
OSC
Ǔ
)4 @
ǒ
N @
ǒ(
B)2
)
@
f
OSC
f
ADC
)OH
CONV
Ǔ
@
ǒ
1
f
OSC
Ǔ
)
ǒ
L
PPRO
f
OSC
Ǔ
Ǔ
(6)
Programmedfor
Self-Control
(PSM=1)
X-Y-Z -Z ScanMode
(ControlByte1
D[6:3]=0000)
1 2
CS Deactivated
Sample,Conversion,
andPreprocessingfor
YCoordinate
Sample,Conversion,
andPreprocessingfor
XCoordinate
Sample,Conversion,
andPreprocessingfor
Z CoordinateandZ Coordinate
1 2
Sample,Conversion,
andPreprocessingfor
YCoordinate
Reading
X-Data
Register
TouchisDetected
Detecting
Touch
Detecting
Touch
Detecting
Touch
Detecting
Touch
Reading
Y-Data
Register
Reading
Z -Data
Register
1
Reading
Z -Data
Register
2
TouchisDetected TouchisDetected
TouchisDetected
PINTDAV Programmed:
As ,
CFR2,D[15:14]=10
PENIRQ
As ,
CFR2,D[15:14]=11or01
DAV
As and ,
CFR2,D[15:14]=00
PENIRQ DAV
t
COORDINATE
Detecting
Touch
TSC2005
SBAS379C DECEMBER 2006 REVISED MARCH 2008
If the pressure of the touch is also to be measured, the process continues in the same way, but measuring the Z
1
and Z
2
values instead, and storing the results in temporary registers. Once the complete sample set of data (X,
Y, Z
1
, and Z
2
) are available, they are loaded in the X, Y, Z
1
, and Z
2
registers. This process is illustrated in
Figure 33 . As before, this process time depends upon the settings previously described. The time for a complete
X, Y, Z
1
, and Z
2
coordinate reading is given by:
Where:
OH2 = overhead time #2 = 3.5 internal clock cycles.
Figure 33. Example of X, Y, and Z Coordinate Touch Screen Scan using TSMode 1
34 Submit Documentation Feedback Copyright © 2006 2008, Texas Instruments Incorporated
Product Folder Link(s): TSC2005